In a laboratory you need to see colours, liquids and details reliably. We design LED lighting with high illuminance, good colour rendering and luminaires that are easy to clean.

High colour rendering for colour reactions and samples.
Low glare when working at fume cupboards and screens.
Sealed luminaires that are easy to clean.

Laboratory work calls for high, even illuminance on the bench, without shadows or reflections. High colour rendering matters whenever colours have to be assessed.
For rooms with strict hygiene or particle requirements we choose sealed luminaires. For true cleanrooms we follow a separate approach in line with ISO 14644.

Research, analysis and education.

ISO and GMP rooms.
More information →
Examination and treatment rooms.
More information →| Room | Em (lux) | UGR max | Ra min |
|---|---|---|---|
| Laboratory, general | 500 | 19 | 80 |
| Colour assessment | 1000 | 16 | 90 |
| Teaching lab | 500 | 19 | 80 |
Guideline values based on EN 12464-1. The lighting plan sets the final values for your situation.
You send us a floor plan or photos. We set the starting point: standards, light levels and savings.
Within 48 hoursDIALux calculation per room with a luminaire schedule, controls and a transparent quotation.
Backed by lux and UGRPremium brands and Lumexa products, installed by our installation partners or your own installer.
On scheduleOn-site inspection, commissioning of the controls and one fixed point of contact for service and warranty.
After handover tooQuestion not listed? Call or email us, we reply within one working day.
Ask your questionTell us about your situation. We reply within one working day and you often have a first lighting proposal within 48 hours.